LGI6501
With efficient regulation, the LGI6501 makes available up to 3.3 kW of charging power with a one-phase power supply and up to 6.5 kW of charging power with a three-phase power supply.
Electrical Data
| Input Variables | |
|---|---|
| Input voltage | 230 V, 50 Hz (47 Hz - 52 Hz) one-phase (L, N) 400 V; 50 Hz (40 Hz - 70 Hz) three-phase (L1, L2, L3) |
| Under-/ overvoltage switch off (option: D) | -30 % / 35 % |
| Input current | <16 A, integrated PFC (Power Factor Correction) Input current limit parameters can be set separately for one-phase and three-phase operation |
| Output Variables | |
| Rated power (50 °C) | 6500 W |
| Max. rated power depending oninput voltage (30 °C) | >7200 W |
| Output voltage 24 V output | 28.0 IU charge (temperature-controlled) |
| Output voltage 144 V output | 167.8 V IU charge (max. 350 W) |
| General Electrical Data | |
| Rated efficiency | >90 % |
| Galvanic isolation | between interfaces, input and output |
| Radio interference | EN 50121-3-2 |
| Potential-free message | 3 message outputs (changeover contact max. 30 V, 0.5 A) |
| Control inputs | 5 control inputs (24 V) |
| Communication | CAN-bus, RS232 (service interface) |
| Fault memory | present |
Mechanical Data
| Display | 7 status LEDs |
| Interfaces | 24 V on-board grid and starter battery: Pfisterer PLUG system service interface: M23 circular plug-in connector all other interfaces: Harting HAN HPR system |
| Ambient temperature | -40 °C to +50 °C (EN 50155 Tx) |
| Cooling | Convection; optional fan kit TA>50 °C |
| Note regarding cooling | do not cover the heat sink; it must be possible for natural convection to occur. |
| Protection class | IP65 |
| Noise emission | noiseless; <45 dB with fan operation with opt. fan kit |
| Casing | self-supporting steel sheet housing for underfloor installation |
| Weight | 90 kg |
| Color | RAL7022 |
Subject to change without prior notice (10/2010)
Datenblatt
| Datasheet LGI6501Format: